skip to main content
research-article

Eyeglasses-free display: towards correcting visual aberrations with computational light field displays

Published:27 July 2014Publication History
Skip Abstract Section

Abstract

Millions of people worldwide need glasses or contact lenses to see or read properly. We introduce a computational display technology that predistorts the presented content for an observer, so that the target image is perceived without the need for eyewear. By designing optics in concert with prefiltering algorithms, the proposed display architecture achieves significantly higher resolution and contrast than prior approaches to vision-correcting image display. We demonstrate that inexpensive light field displays driven by efficient implementations of 4D prefiltering algorithms can produce the desired vision-corrected imagery, even for higher-order aberrations that are difficult to be corrected with glasses. The proposed computational display architecture is evaluated in simulation and with a low-cost prototype device.

Skip Supplemental Material Section

Supplemental Material

a59-sidebyside.mp4

mp4

13.2 MB

References

  1. Akeley, K., Watt, S. J., Girshick, A. R., and Banks, M. S. 2004. A stereo display prototype with multiple focal distances. ACM Trans. Graph. (SIGGRAPH) 23, 3, 804--813. Google ScholarGoogle ScholarDigital LibraryDigital Library
  2. Alonso Jr., M., and Barreto, A. B. 2003. Pre-compensation for high-order aberrations of the human eye using on-screen image deconvolution. In IEEE Engineering in Medicine and Biology Society, vol. 1, 556--559.Google ScholarGoogle ScholarCross RefCross Ref
  3. Archand, P., Pite, E., Guillemet, H., and Trocme, L., 2011. Systems and methods for rendering a display to compensate for a viewer's visual impairment. International Patent Application PCT/US2011/039993.Google ScholarGoogle Scholar
  4. Byrd, R. H., Lu, P., Nocedal, J., and Zhu, C. 1995. A limited memory algorithm for bound constrained optimization. SIAM J. Sci. Comput. 16, 5 (Sept.), 1190--1208. Google ScholarGoogle ScholarDigital LibraryDigital Library
  5. Chai, J.-X., Tong, X., Chan, S.-C., and Shum, H.-Y. 2000. Plenoptic sampling. In ACM SIGGRAPH, 307--318. Google ScholarGoogle ScholarDigital LibraryDigital Library
  6. Cossairt, O. S., Napoli, J., Hill, S. L., Dorval, R. K., and Favalora, G. E. 2007. Occlusion-capable multiview volumetric three-dimensional display. Applied Optics 46, 8, 1244--1250.Google ScholarGoogle ScholarCross RefCross Ref
  7. Durand, F., Holzschuch, N., Soler, C., Chan, E., and Sillion, F. X. 2005. A frequency analysis of light transport. In Proc. SIGGRAPH, 1115--1126. Google ScholarGoogle ScholarDigital LibraryDigital Library
  8. Gortler, S. J., Grzeszczuk, R., Szeliski, R., and Cohen, M. F. 1996. The lumigraph. In Proc. SIGGRAPH, SIGGRAPH '96, 43--54. Google ScholarGoogle ScholarDigital LibraryDigital Library
  9. Hecht, E. 2001. Optics (Fourth Edition). Addison-Wesley.Google ScholarGoogle Scholar
  10. Hirsch, M., Wetzstein, G., and Raskar, R. 2014. A compressive light field projection system. ACM Trans. Graph. (SIGGRAPH) 33. Google ScholarGoogle ScholarDigital LibraryDigital Library
  11. Huang, F.-C., and Barsky, B. 2011. A framework for aberration compensated displays. Tech. Rep. UCB/EECS-2011-162, University of California, Berkeley, December.Google ScholarGoogle Scholar
  12. Huang, F.-C., Lanman, D., Barsky, B. A., and Raskar, R. 2012. Correcting for optical aberrations using multilayer displays. ACM Trans. Graph. (SIGGRAPH Asia) 31, 6, 185:1--185:12. Google ScholarGoogle ScholarDigital LibraryDigital Library
  13. Ives, F. E., 1903. Parallax stereogram and process of making same. U.S. Patent 725,567.Google ScholarGoogle Scholar
  14. Jones, A., McDowall, I., Yamada, H., Bolas, M., and Debevec, P. 2007. Rendering for an interactive 360° light field display. ACM Trans. Graph. (SIGGRAPH) 26, 40:1--40:10. Google ScholarGoogle ScholarDigital LibraryDigital Library
  15. Lanman, D., and Luebke, D. 2013. Near-eye light field displays. ACM Trans. Graph. (SIGGRAPH Asia) 32, 6, 220:1--220:10. Google ScholarGoogle ScholarDigital LibraryDigital Library
  16. Lanman, D., Hirsch, M., Kim, Y., and Raskar, R. 2010. Content-adaptive parallax barriers: optimizing dual-layer 3D displays using low-rank light field factorization. ACM Trans. Graph. 29, 163:1--163:10. Google ScholarGoogle ScholarDigital LibraryDigital Library
  17. Levin, A., Hasinoff, S. W., Green, P., Durand, F., and Freeman, W. T. 2009. 4D frequency analysis of computational cameras for depth of field extension. ACM Trans. Graph. (SIGGRAPH) 28, 3. Google ScholarGoogle ScholarDigital LibraryDigital Library
  18. Levoy, M., and Hanrahan, P. 1996. Light field rendering. In Proc. SIGGRAPH, 31--42. Google ScholarGoogle ScholarDigital LibraryDigital Library
  19. Lippmann, G. 1908. Épreuves réversibles donnant la sensation du relief. Journal of Physics 7, 4, 821--825.Google ScholarGoogle Scholar
  20. Love, G., Hoffman, D., Hands, P., Gao, J., Kirby, A., and Banks, M. 2009. High-speed switchable lens enables the development of a volumetric stereoscopic display. Optics Express 17, 15716--15725.Google ScholarGoogle ScholarCross RefCross Ref
  21. Maimone, A., Wetzstein, G., Hirsch, M., Lanman, D., Raskar, R., and Fuchs, H. 2013. Focus 3d: Compressive accommodation display. ACM Trans. Graph. 32, 5, 153:1--153:13. Google ScholarGoogle ScholarDigital LibraryDigital Library
  22. Mantiuk, R., Kim, K. J., Rempel, A. G., and Heidrich, W. 2011. Hdr-vdp-2: a calibrated visual metric for visibility and quality predictions in all luminance conditions. In Proc. ACM SIGGRAPH, 40:1--40:14. Google ScholarGoogle ScholarDigital LibraryDigital Library
  23. Masia, B., Wetzstein, G., Didyk, P., and Gutierrez, D. 2013. A survey on computational displays: Pushing the boundaries of optics, computation, and perception. Computers & Graphics 37, 8, 1012--1038. Google ScholarGoogle ScholarDigital LibraryDigital Library
  24. Ng, R., and Hanrahan, P. 2006. Digital correction of lens aberrations in light field photography. In Proc. SPIE International Optical Design.Google ScholarGoogle Scholar
  25. Ng, R. 2005. Fourier slice photography. In ACM SIGGRAPH 2005 Papers, ACM, New York, NY, USA, SIGGRAPH '05, 735--744. Google ScholarGoogle ScholarDigital LibraryDigital Library
  26. Pamplona, V. F., Mohan, A., Oliveira, M. M., and Raskar, R. 2010. Netra: interactive display for estimating refractive errors and focal range. ACM Trans. Graph. (SIGGRAPH) 29, 77:1--77:8. Google ScholarGoogle ScholarDigital LibraryDigital Library
  27. Pamplona, V. F., Passos, E. B., Zizka, J., Oliveira, M. M., Lawson, E., Clua, E., and Raskar, R. 2011. Catra: interactive measuring and modeling of cataracts. ACM Trans. Graph. (SIGGRAPH) 30, 4, 47:1--47:8. Google ScholarGoogle ScholarDigital LibraryDigital Library
  28. Pamplona, V., Oliveira, M., Aliaga, D., and Raskar, R. 2012. Tailored displays to compensate for visual aberrations. ACM Trans. Graph. (SIGGRAPH) 31. Google ScholarGoogle ScholarDigital LibraryDigital Library
  29. Ramamoorthi, R., Mahajan, D., and Belhumeur, P. 2007. A first-order analysis of lighting, shading, and shadows. ACM Trans. Graph. 26, 1. Google ScholarGoogle ScholarDigital LibraryDigital Library
  30. Takaki, Y. 2006. High-Density Directional Display for Generating Natural Three-Dimensional Images. Proc. IEEE 94, 3.Google ScholarGoogle ScholarCross RefCross Ref
  31. Vitale, S., Sperduto, R. D., and Ferris, III, F. L. 2009. Increased prevalence of myopia in the United States between 1971--1972 and 1999--2004. Arch. Ophthalmology 127, 12, 1632--1639.Google ScholarGoogle ScholarCross RefCross Ref
  32. Wetzstein, G., Lanman, D., Heidrich, W., and Raskar, R. 2011. Layered 3D: tomographic image synthesis for attenuation-based light field and high dynamic range displays. ACM Trans. Graph. (SIGGRAPH) 30, 4. Google ScholarGoogle ScholarDigital LibraryDigital Library
  33. Wetzstein, G., Lanman, D., Hirsch, M., and Raskar, R. 2012. Tensor displays: Compressive light field synthesis using multilayer displays with directional backlighting. ACM Trans. Graph. (SIGGRAPH) 31. Google ScholarGoogle ScholarDigital LibraryDigital Library
  34. Wong, T. Y., Foster, P. J., Hee, J., Ng, T. P., Tielsch, J. M., Chew, S. J., Johnson, G. J., and Seah, S. K. 2000. Prevalence and risk factors for refractive errors in adult chinese in singapore. Invest Ophthalmol Vis Sci 41, 9, 2486--94.Google ScholarGoogle Scholar
  35. Yellott, J. I., and Yellott, J. W. 2007. Correcting spurious resolution in defocused images. Proc. SPIE 6492.Google ScholarGoogle Scholar

Index Terms

  1. Eyeglasses-free display: towards correcting visual aberrations with computational light field displays

          Recommendations

          Comments

          Login options

          Check if you have access through your login credentials or your institution to get full access on this article.

          Sign in

          Full Access

          • Published in

            cover image ACM Transactions on Graphics
            ACM Transactions on Graphics  Volume 33, Issue 4
            July 2014
            1366 pages
            ISSN:0730-0301
            EISSN:1557-7368
            DOI:10.1145/2601097
            Issue’s Table of Contents

            Copyright © 2014 ACM

            Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

            Publisher

            Association for Computing Machinery

            New York, NY, United States

            Publication History

            • Published: 27 July 2014
            Published in tog Volume 33, Issue 4

            Permissions

            Request permissions about this article.

            Request Permissions

            Check for updates

            Qualifiers

            • research-article

          PDF Format

          View or Download as a PDF file.

          PDF

          eReader

          View online with eReader.

          eReader